iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page 8 Dukane Manual Part Number 403-572-03
Pre-triggerSwitchAdjustment - The pre-trigger switch
option starts the horn vibrating before contacting the part
to be welded. To ensure safe operation, adjust the pre-
trigger so the ultrasound signal will not activate if the
horn is more than ¼ in (7 mm) from the part to be welded.
SystemElectrical Cabling- Electrical power must be
off when connecting or disconnecting electrical cables.
Do NotWear Loose Clothing orJewelry - They can
become caught in moving parts.
StayAlert - Watch what you are doing at all times. Use
common sense. Do not operate the press when you are
tired or distracted from the job at hand.
Do not Operate the Equipment - Your judgement or
reexes could be impaired while taking prescription medi-
cations. If so, do not operate the equipment. Be familiar
with warning labels and recommended activity restrictions
that accompany your prescription medications. If you have
any doubt, do not operate the equipment.
General Considerations
CAUTION
Parts being joined ultrasoni-
cally will at times vibrate at
audible frequencies. Wear ear
protectors to reduce annoying
or uncomfortable sounds. In addition,
ultrasound bafes, sound enclosures,
or materials that absorb sound may
be located to surround the system.
WARNING
Keep head, hands, limbs
and body at least six inch-
es (152 mm) away from an
operating press/thruster.
A vibrating, descending horn can cause
burns and/or crushing injuries.
CAUTION
Plastics Health Notice
Certain plastic materials, when being processed, may
emit fumes and/or gases that may be hazardous to the
operators health. Proper ventilation of the work station
should be provided where such materials are processed.
Inquiries should be made to the U.S. Department of Labor
concerning OSHA regulations for a particular plastic prior
to processing with Dukane ultrasonic equipment.
Electrical Safety
The iQ Series generator provides the operating power
and power returns. Make sure the generator is grounded
properly.
In addition to the safety considerations, proper grounding
is essential for the effective suppression of RFI (Radio
Frequency Interference). Every generator contains a RFI
lter which blocks noise on the AC power line from enter-
ing the generator control circuitry. This lter also prevents
ultrasonic RFI from being fed back into the AC power line.
If you experience problems with RFI from the press, run
an additional grounding wire from the press base ground-
ing stud to the nearest grounded metal pipe or equivalent
earth ground by means of a ground clamp. Use at least 14
AWG wire for the connection to the press base.
Continued from Previous Page
Continued
When making cable connec-
tions to system equipment or
disconnecting cables from
system equipment, make
sure electrical power to the system is
turned off, and AC power cords are re-
moved from their receptacles. After the
cables have been securely connected and
the connections and cable routing checked
a nal time, the power may be restored.